Sentrum List X Facility, Woking
High power and
cooling density facility ideal for disaster recovery & SAN to SAN
replication
Adapt’s M25 periphery facility is based at Sentrum’s state of-the-art data centre in
Woking, Surrey. Sentrum is a high security List X grade building offering
high power and cooling density and its location is ideal for split site solutions.
The Woking site is connected to Adapt’s UK data centre network via resilient links, enabling load balancing and synchronous replication across multiple
production environments.
Take the tour
To arrange a tour of the Sentrum List X facility or to discuss your unique requirements in more detail, call us on 0203 009 3300 or complete the form to the right.
Facility overview
- Building size: 18,000m2
- High density solutions: 2,000 watts per sq
metre
- 24/7 critical monitoring
- 24/7 secure access to data centre
- Adapt’s Phase One development: 500m2
Connectivity
Data centre connectivity is available through multiple
networks and service providers for network resilience. Adapt offers a broad range of choice and flexibility:
- IP transit from a choice of Tier 1 IP providers
- MPLS for higher bandwidth and low latency data
transfer
- Resilient inter-site data centre connectivity to
networked data centres
Adapt's inter-site data centre connectivity allows customers to benefit from our diversely routed
core fibre network, providing:
- Managed 1 Gig Ethernet
- Managed 10 Gig Ethernet
- Fibre channel
- IP and Layer 2 services
- Wavelengths
Space and power
options
Adapt will work with you to deisng the most appropriate environment for your servers and IT infrastructure:
- Caged private areas with a range of enhanced
security offerings
- Custom builds, bespoke to unique
requirements
- Power density options from 7kW (32 Amp)
intelligent racks as standard, to 14kW CAC up to 20kW water cooled
Building
- High density solutions – 2,000 watts per sq
metre
- 24/7 building operation
- 750mm raised floor with 4 metres to underside of
floor
- Secure managed delivery bay with 3 goods lifts
- Floor loading 10KN per sq metre
- The facility will be SAS70 Type II certified
Power
- Two separate mains feeds from the utility
provider (mains power supplied via 2 x 66kV incomers)
- Minimum N+1 redundancy of power to the data
centre
- Diverse A and B supplies to every cabinet
- 8 UPS units spread across 2 locations for
resilience
- 5 diesel generators (4 are required to run the
data centre at full load)
- 72 hours of fuel stored on site for generators
- Emergency provisions in place for extra fuel.
- N+N or N+1 power solutions can be tailor-made to
meet customer requirements
- N+N Uninterruptible Power Supplies (UPS) with
battery back up – min 10 minute run time
- 60 back up generators – 3 per suite
- Re-fuelling contracts to ensure timely replacement
- Maintenance for generators – weekly start,
yearly load test, quarterly service/check
Cooling
- Primary cooling infrastructure, centrally managed
and linked to Building Management System (BMS)
- Room air conditioning units are external to the
suite
- Regulated humidity
- Minimum N+1 standby on all cooling systems -
chilled water, DX options
- Primary cooling infrastructure, centrally
managed and linked to Building Management System (BMS)
Fire detection and suppression
- Three-stage fire detection systems in all plant
areas – Novak suppression
- VESDA (Very Early Smoke Detection Apparatus)
- Fire detection in all rooms, below raised floors
and in ceiling voids
- Double interlocked pre-action gas suppression to
technical areas – Argonite Gas
- Fire detection and suppression systems
interconnected to central BMS
Security
- 24/7 on-site security – Sentrum employed (no
contractors)
- Door access controls at site and building
entrances
- Proximity cards to authorize access levels
- Mantrap access to all client areas with
biometric readers
- External and internal CCTV
- Intruder detection alarms
- Double 3 metres secure perimeter fence with
trembler wire
- Vehicle trap at site entrance controlled by an
electronic sliding security gate supported by anti-ram barriers
Building Management
Systems
- Power monitoring and Building Management Systems
to provide alarms
- Power surge management
- Dedicated in-house 24/7 facilities management
team
- Planned preventative maintenance programs
Connectivity
- Multiple access building entry points for
diverse routing of communications
- Diverse cable routing into facility
- Diverse cable routing through raised floor to
each suite
- Strict cable management policy
- Carriers on site are BT, COLT, Virgin Media
(NTL)
Ancillary Space
- Dedicated office space
- De-box and test rooms
- Office recovery suites
- Integrated with our other UK data centres
- M25 periphery for DR option
- Security compliant List-X security rated
- Various transport offerings
- Synchronous SAN to SAN replication
- Flexible power solutions
- kW commercial models - cost per kW/amp
- Data centre consolidation
- IP connectivity through multiple networks and
service providers
- Rapid deployment of custom build private suites
- Managed data centre infrastructure
- Flexible contract terms
- Intelligent integrated active server enclosures
- Environmental sensors included as standard
- Secure local & remote cabinet access system